3D-printed Guided Mode Resonance Readout System for Biomedical and Environmental Applications

Authors

DOI:

https://doi.org/10.4186/ej.2021.25.6.35 Full article

Abstract

This paper demonstrates design and development of an open-source platform-based reflection spectroscopy readout system for guided mode resonance (GMR) sensing applications. The GMR dimensions, reflection grating period, imaging system and components orientations are optimized to enhance the angular resolution while sustaining resonance excitation within the visible range. To achieve the needed arrangement of the multiple components, 3D printing is utilized to build the mechanical mounting. The reflection spectra are extracted from the webcam images and processed using a software written on raspberry-pi computational unit. This ensures the compactness and portability of the system. The system performance of the transducer is tested by measuring the changes in the refractive index of the environment at the GMR chip interface.

Keywords:

guided mode resonance, spectrometer, open-source platform, refractive index sensing, 3D printing

Affiliations

  • Hironmay Deb Bangkok University
  • Nantarat Srisuai National Electronics and Computer Technology Center (NECTEC), Thailand
  • Sakoolkan Bonruang National Electronics and Computer Technology Center (NECTEC), Thailand
  • Romuald Jolivot Bangkok University
  • Chamras Promptmas Mahidol University
  • Waleed S. Mohammed Bangkok University

Corresponding author: Hironmay Deb, deb.hironmay@gmail.com

1310 1105

Author Biographies

  • Center of Research in Optoelectronics, Communication and Computational Systems (BU-CROCCS), School of Engineering, Bangkok University, Pathum Thani 12120, Thailand

  • Opto-Electrochemical Sensing Research Team (OEC), Spectroscopic and Sensing Devices Research Group (SSDRG), National Electronics and Computer Technology Center (NECTEC), Pathum Thani 12120, Thailand

  • Opto-Electrochemical Sensing Research Team (OEC), Spectroscopic and Sensing Devices Research Group (SSDRG), National Electronics and Computer Technology Center (NECTEC), Pathum Thani 12120, Thailand

  • Center of Research in Optoelectronics, Communication and Computational Systems (BU-CROCCS), School of Engineering, Bangkok University, Pathum Thani 12120, Thailand

  • Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom 73170, Thailand

  • Center of Research in Optoelectronics, Communication and Computational Systems (BU-CROCCS), School of Engineering, Bangkok University, Pathum Thani 12120, Thailand

Downloads

How to Cite

[1]
H. Deb, N. Srisuai, S. Bonruang, R. Jolivot, C. Promptmas, and W. S. Mohammed, “3D-printed Guided Mode Resonance Readout System for Biomedical and Environmental Applications”, Eng. J., vol. 25, no. 6, pp. 35–43, Jun. 2021, doi: 10.4186/ej.2021.25.6.35.

Citations

Published

2021-06-30

Issue

Section

Modern Engineering Technology