Sensitivity Analysis by the 2k Factorial Experimental Design of CO2 Capture with Amine Gas Treating Process Using Aspen Plus

Authors

DOI:

https://doi.org/10.4186/ej.2021.25.4.95 Full article

Abstract

It is well-known that CO2 capture with amine treating process has been used and developed in industry to purify the off-gas from the process. Nowadays, the simulation via computer software is one of the most effective tools to improve and optimize the existing process because there is no environmental effect and uses lower cost compared to the experiments. Generally, for sensitivity analysis, the parameters are studied individually without considering the interaction effects between parameters. In this study, the equilibrium model of CO2 capture by monoethanolamine (MEA) pilot plant was modelled using Aspen Plus by ENRTL-RK thermodynamics property model. A sensitivity analysis with the 2k factorial experimental design was performed. The main and interaction effects of five parameters (which are liquid-gas mass ratio (L/G), sour gas temperature, lean MEA temperature, lean MEA concentration and CO2 concentration in sour gas) were then investigated. From the sensitivity analysis with the 2k factorial experimental design, liquid-gas mass ratio contributed 75.82% to CO2 removal efficiency; while CO2 concentration in sour gas and liquid-gas mass ratio (L/G) occupied 29.14% and 17.36% to CO2 removal efficiency and specific heat duty at the reboiler, respectively.

Keywords:

CO2 capture, simulation, Aspen Plus, sensitivity analysis, 2k factorial experiment design

Affiliations

  • Thapanat Chuenphan Covestro (Thailand) Co., Ltd.
  • Tarabordin Yurata Chulalongkorn University
  • Teerawat Sema Chulalongkorn University
  • Benjapon Chalermsinsuwan Chulalongkorn University

Corresponding author: Benjapon Chalermsinsuwan, benjapon.c@chula.ac.th

2068 1285

Author Biographies

  • Covestro (Thailand) Co., Ltd., 4-4/1 I-8 Road, Map Ta Phut Industrial Estate, Muang, Rayong 21150, Thailand

    Program of Petrochemistry and Polymer Science, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand

  • Department of Chemical Technology, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand

  • Department of Chemical Technology, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand

    Fuels Research Center, Department of Chemical Technology, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand

    Center of Excellence on Petrochemical and Materials Technology, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand

  • Department of Chemical Technology, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand


    Fuels Research Center, Department of Chemical Technology, Faculty of Science, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand


    Center of Excellence on Petrochemical and Materials Technology, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand

     

    Advanced Computational Fluid Dynamics Research Unit, Chulalongkorn University, 254 Phayathai Road, Pathumwan, Bangkok 10330, Thailand                                                                                                                  

Downloads

How to Cite

[1]
T. Chuenphan, T. Yurata, T. Sema, and B. Chalermsinsuwan, “Sensitivity Analysis by the 2k Factorial Experimental Design of CO2 Capture with Amine Gas Treating Process Using Aspen Plus”, Eng. J., vol. 25, no. 4, pp. 95–104, Apr. 2021, doi: 10.4186/ej.2021.25.4.95.

Citations

Published

2021-04-30

Issue

Section

Special Section for TIChE 2020