Micro-Needle with Polygonal Structure of Micro-Channel for Stress and Blood or Drug Flow Optimization

Authors

DOI:

https://doi.org/10.4186/ej.2017.21.4.207 Full article

Abstract

This paper presents micro-needle with different tip and inner structure of the needle for optimizations of pain stresses and drug or blood deliveries. The micro-needle comes with several design's parameters of length ranging from 5 mm to 50 mm and diameter ranging from 100 µm to 200 µm. A hollow micro-needle with four different tip designs which are 10°, D3-2, D6 and Quadruple are also designed to optimize the pain stresses parameters. In order to improve the flow deliveries, the inner structure of the channel is modified into various polygonal shape which is square, hexagon and dodecagon. It shows that, having less contact surface area between the skin and micro-needle's tip and polygonal shape of inner channel has better performance for both of the objectives. These feasible region of average velocity and stress of the micro-needle have satisfied in determining the best design for tip and inner channel of the micro-needle under certain conditions and constraints. The three-dimensional geometry study had improved the insertions performance and efficiencies in painless drug or blood deliveries.

Affiliations

  • Mohd Danial Ibrahim University of Malaysia, Sarawak
  • Yana Shaheera Yunos University of Malaysia, Sarawak
  • Nobuo Watanabe Shibaura Institute of Technology
  • Nur Alia Athirah Mohtadzar University of Malaysia, Sarawak
  • Siti Noor Haizum Semait Press Metal Bintulu Sdn. Bhd.
  • Andrew Ragai Henry Rigit University of Malaysia, Sarawak
  • Yuta Sunami Tokai University
  • Wong Lee Kwang University of Malaysia, Sarawak
  • Mohd Rahmat A. Rahman University of Malaysia, Sarawak
  • Muhammad Zaidi Mohtar University of Malaysia, Sarawak

Corresponding author: Mohd Danial Ibrahim, imdanial@unimas.my

1953 1432

Author Biographies

  • Department of Mechanical & Manufacturing, Universiti Malaysia Sarawak, 94300 Kota Samarahan, Malaysia

  • Department of Mechanical & Manufacturing, Universiti Malaysia Sarawak, 94300 Kota Samarahan, Malaysia

  • Department of Bioscience and Engineering, Shibaura Institute of Technology, Saitama Prefecture 337-8570, Japan

  • Department of Electrical & Electronic, Universiti Malaysia Sarawak, 94300 Kota Samarahan, Malaysia

  • Press Metal Bintulu Sdn. Bhd., 97000 Samalaju, Malaysia

  • Department of Mechanical & Manufacturing, Universiti Malaysia Sarawak, 94300 Kota Samarahan, Malaysia

  • Department of Mechanical Engineering, Tokai University, Kanagawa Prefecture 259-1207, Japan

  • Department of Mechanical & Manufacturing, Universiti Malaysia Sarawak, 94300 Kota Samarahan, Malaysia

  • Department of Mechanical & Manufacturing, Universiti Malaysia Sarawak, 94300 Kota Samarahan, Malaysia

  • Department of Mechanical & Manufacturing, Universiti Malaysia Sarawak, 94300 Kota Samarahan, Malaysia

Downloads

How to Cite

[1]
M. D. Ibrahim et al., “Micro-Needle with Polygonal Structure of Micro-Channel for Stress and Blood or Drug Flow Optimization”, Eng. J., vol. 21, no. 4, pp. 207–216, Jul. 2017, doi: 10.4186/ej.2017.21.4.207.

Citations

Published

2017-07-31

Issue

Section

Modern Engineering Technology